Wagner Sprint Error Codes Reference
Sprint
Error and warning code reference for the Wagner EPG Sprint X powder controller: code meanings, causes, and remedies for troubleshooting Sprint X and XE systems. Free PDF download from CET.
Inside This Document
Six-page troubleshooting reference for the EPG-SPRINT X control unit used on Wagner Sprint X and Sprint XE manual powder systems, compiled by CET from the official operating manual. It explains how the fault LED and seven-segment display signal warnings E01–E04 (work can continue) versus hard errors, then lists each code with its cause and remedy — for example E01, atomizing air too low, caused by a kinked or blocked hose. It also reproduces Wagner's safety requirements for maintenance and repair work, including de-energizing and depressurizing the gun before service. The first document to check when a Sprint controller shows "Exx" on the display.
From the Document
EPG-SPRINT X OPERATING MANUAL 11 TROUBLESHOOTING AND RECTIFICATION Incorrect maintenance/repair! Danger to life and damage to the device. Wagner devices, protective systems and safety, monitoring and control equipment may only be repaired as defined in Directive 94/9/EC (ATEX) by trained Wagner service personnel or capable persons in accordance with TRBS 1203! Note national regulations! Repair or replacement of devices or parts of devices may only be performed outside the hazard area! DANGER Incorrect maintenance/repair! Risk of injury and damage to the device. Have repairs and part replacements carried out only by specially trained staff or a WAGNER service center. Before all work on the device and in the event of work interruptions: - Switch off the energy/compressed air supply. - Relieve spray gun and device pressure. - Secure the spray gun against actuation. Observe the operating manual and service manuals at all times when carrying out work. DANGER Distributed by Coating Equipment Technology Inc EPG-SPRINT X P_01760 EPG SPRINT X 0 % 10 20 30 40 50 Ø 12 10 11 9 8 m /h 2.0 3.0 0.5 0.3 0.1 1.5 3 5.5 4.5 3.5 2.5 80 100 % Tri 90 60 70 19 13 OPERATING MANUAL 11.1 WARNINGS E01-E04 The fault LED 13 flashes to indicate warnings. In addition "Exx" is shown alternately in the LED display 19 (7-segment LED) (xx stands for the warning number). Work can continue if a warning is displayed. Distributed by Coating Equipment Technology Inc EPG-SPRINT X OPERATING MANUAL Warning No. Warning Cause Remedy E01 Atomizing air too low Set point cannot be reached Causes: Hose kinked / blocked…
Document Details
- Brand
- Wagner
- Type
- Selection Guide
- Product Line
- Sprint
- Pages
- 6
- Language
- en
Related Documents
Wagner 2021 Liquid Catalog
Wagner catalog for the Wagner 2021 Liquid Catalog. 211-page PDF — view online or download free from CET.
Wagner DN 2.6 Paint & Dosing Manual
DN 2.6
Wagner DN 2.6 paint and dosing valve manual covering PV 100/400, DV 100/400, and GA 250PV/400PV/400DV — installation and service. 60-page PDF, free.
Wagner E-Line Brochure
E-Line
Wagner product brochure for the E-Line. 4-page PDF — view online or download free from CET.
Wagner GM5000 Spray Packs
GM5000
Wagner product brochure for the GM5000. 2-page PDF — view online or download free from CET.